• HOME
  • ABOUT US
    • ABOUT US
    • MILESTONES
    • BUSINESS STRUCTURE
    • OUR CULTURE
  • NEWS
  • PRODUCTS
    • BUSINESS SCOPE
    • PRODUCTS CENTER
  • SOLUTIONS
    • DOMESTIC FIRE ALARM MONITORING
    • INTELLIGENT FIRE ALARM
    • COMBUSTIBLE GAS DETECTION IOT
    • SMART ELECTRICITY SAFETY WARNING
    • INTELLIGENT FIRE WATER MONITORING
  • CSR
  • CASES
  • JOIN US
    • TALENT PROSPECT
    • MANAGEMENT MODEL
    • WORKING ENVIRONMENT
    • EMPLOYEE EVENTS
  • CONTACT US
    • Shenzhen Office (SZ)
    • HKSAR Office
    • Logistics Center (HKSAR)
    • SHOP
    • 中文(简)
    • 中文(繁)
    • English
HOME PRODUCTS CENTER PRODUCTS DETAIL

MINI-968/10Y

Battery Typed CO Alarm

Combustible gas detection system

MINI968/10Y is an independent combustible gas detector for measuring artificial gas. It is made of high quality gas sensor, combined with advanced electronic technology and sophisticated technology. In the place where artificial gas exists, once the concentration of carbon monoxide gas reaches the alarm setting value, the detector will faithfully issue an audible and visual alarm signal to remind you to take effective measures immediately; Or start the linkage device, ventilation or close the air source, eliminate dangerous situations, and effectively avoid the occurrence of fire, explosion, poisoning and other malignant accidents.

Microprocessor control, high reliability, low false positives;

On-site sound and light alarm

Applicable Scenarios

null

Certification

null

Battery Typed CO Alarm
Product Parameters

Model#

MINI-968/10Y

Battery life

10 Year

Sensor

CO

Size

40 x 32 x 75mm

Gross weight

67g(including battery)

Alarm setting value

50 PPM (60-90 mins) 100 PPM (10-40 mins) 300 PPM (<3 mins)

Alarm signal

Sound, RED LED flashing

Sound level

≥85dB@3m

Battery

3V

Silence duration

80s

Operational temperature

0℃~55℃

Operational humdity

≤93%

More Products

Fire extinguisher (dry powder)

Fire extinguisher (dry powder)

Model#

MF/ABCE5C

Fire suppression class

1A,21B,C,E

View All
Water based fire extinguisher

Water based fire extinguisher

Model#

MS/ABEF9

Fire suppression class

2A,89B,E

View All
10Y Smoke Alarm (RF)

10Y Smoke Alarm (RF)

Model#

SS-368NB

Battery life

10 Year

View All
Point type optical inductance temperature fire detector

Point type optical inductance temperature fire detector

Wire system

Non-polar bibus

Bus voltage

DC24V(18V-28V)

View All
Filter fire rescue breathing apparatus(Plastic box)

Filter fire rescue breathing apparatus(Plastic box)

Model#

TZL30A

Product name

Filter fire rescue breathing apparatus

View All
Optical Smoke Alarm 
Mains Powered with Battery  Back-up

Optical Smoke Alarm Mains Powered with Battery Back-up

Wire system

Connect the interconnect

Voltage

220-240VAC

View All
Input module

Input module

Standard

GB 16806-2006

Voltage

DC24V(18V-28V)

View All
Output module

Output module

Standard

GB 16806-2006

Operation voltage

DC24V(18V-28V)

View All
Combined electrical fire monitoring detector

Combined electrical fire monitoring detector

Power supply

DC10V-DC42V is centrally powered by a monitor, regional extension, or regional repeater

Total communication mode

F-BUS Fire Two bus

View All
Fire extinguisher (dry powder)

Fire extinguisher (dry powder)

Model#

MF/ABCE5C

Fire suppression class

1A,21B,C,E

View All
Water based fire extinguisher

Water based fire extinguisher

Model#

MS/ABEF9

Fire suppression class

2A,89B,E

View All
10Y Smoke Alarm (RF)

10Y Smoke Alarm (RF)

Model#

SS-368NB

Battery life

10 Year

View All
Point type optical inductance temperature fire detector

Point type optical inductance temperature fire detector

Wire system

Non-polar bibus

Bus voltage

DC24V(18V-28V)

View All
Filter fire rescue breathing apparatus(Plastic box)

Filter fire rescue breathing apparatus(Plastic box)

Model#

TZL30A

Product name

Filter fire rescue breathing apparatus

View All
Optical Smoke Alarm 
Mains Powered with Battery  Back-up

Optical Smoke Alarm Mains Powered with Battery Back-up

Wire system

Connect the interconnect

Voltage

220-240VAC

View All
Input module

Input module

Standard

GB 16806-2006

Voltage

DC24V(18V-28V)

View All
Output module

Output module

Standard

GB 16806-2006

Operation voltage

DC24V(18V-28V)

View All
Combined electrical fire monitoring detector

Combined electrical fire monitoring detector

Power supply

DC10V-DC42V is centrally powered by a monitor, regional extension, or regional repeater

Total communication mode

F-BUS Fire Two bus

View All

HOME

ABOUT US

  • ABOUT US
  • MILESTONES
  • BUSINESS STRUCTURE
  • OUR CULTURE

NEWS

PRODUCTS

  • BUSINESS SCOPE
  • PRODUCTS CENTER

SOLUTIONS

  • DOMESTIC FIRE ALARM MONITORING
  • INTELLIGENT FIRE ALARM
  • COMBUSTIBLE GAS DETECTION IOT
  • SMART ELECTRICITY SAFETY WARNING
  • INTELLIGENT FIRE WATER MONITORING

CSR

CASES

JOIN US

  • TALENT PROSPECT
  • MANAGEMENT MODEL
  • WORKING ENVIRONMENT
  • EMPLOYEE EVENTS

CONTACT US

  • Shenzhen Office (SZ)
  • HKSAR Office
  • Logistics Center (HKSAR)
  • SHOP

Copyrights ©2021 GartecTechnology Co., Ltd 嘉达科建. All rights reserved

Copyrights ©2021 GartecTechnology Co., Ltd
嘉达科建. All rights reserved