• HOME
  • ABOUT US
    • ABOUT US
    • MILESTONES
    • BUSINESS STRUCTURE
    • OUR CULTURE
  • NEWS
  • PRODUCTS
    • BUSINESS SCOPE
    • PRODUCTS CENTER
  • SOLUTIONS
    • DOMESTIC FIRE ALARM MONITORING
    • INTELLIGENT FIRE ALARM
    • COMBUSTIBLE GAS DETECTION IOT
    • SMART ELECTRICITY SAFETY WARNING
    • INTELLIGENT FIRE WATER MONITORING
  • CSR
  • CASES
  • JOIN US
    • TALENT PROSPECT
    • MANAGEMENT MODEL
    • WORKING ENVIRONMENT
    • EMPLOYEE EVENTS
  • CONTACT US
    • Shenzhen Office (SZ)
    • HKSAR Office
    • Logistics Center (HKSAR)
    • SHOP
    • 中文(简)
    • 中文(繁)
    • English
HOME PRODUCTS CENTER PRODUCTS DETAIL

GT300-64

Electrical Fire Monitoring System

Electrical fire monitoring system

With the terminal controller, regional extension, regional repeater, sensors, etc., flexible construction of large-capacity electrical fire monitoring system, the system adopts non-open operation mode, self-management within the system, external one-way transmission of information by centralized power supply, to provide DC24V safety voltage power supply to the field sensor, effectively ensure the stability and safety of the system;

The system can be flexibly expanded through the regional extension to adapt to the complex and changing requirements of modern buildings to monitor the line current value and temperature value information of all monitored fire control boxes in real time, and transmit the working status and alarm information to the graphic display device of the fire control room. The monitor can output 2 communication loops, the communication capacity is 2x512 =1024 sensor system adopts F-BUS fire two bus as the communication platform to ensure the reliable and stable operation of the system in various electromagnetic environments.

Applicable Scenarios

null

Certification

null

Electrical Fire Monitoring System
Product Parameters

Power supply

AC220V±1 5% 50HZ(Fire power supply)

Output voltage

DC24V

Communication mode

F-BUS 2-Wires

Input power

250W

Operation level

There are 3 operation levels, which are suitable for different levels of operators

Record feature

≥10000 pieces

More Products

Optical Smoke Alarm 
Mains Powered with Battery  Back-up

Optical Smoke Alarm Mains Powered with Battery Back-up

Wire system

Connect the interconnect

Voltage

220-240VAC

View All
Battery Typed CO Alarm

Battery Typed CO Alarm

Model#

MINI-968D

Battery life

1-10 years

View All
Manual fire alarm button

Manual fire alarm button

Standard

GB 19880-2005

Voltage

DC24V(18V-28V)

View All
Water based fire extinguisher

Water based fire extinguisher

Model#

MSWJ620

Fire suppression class

0.5A,8B,E,5F

View All
Photoelectric Smoke and Heat Alarm
Mains Powered with 10 Year Rechargeable Battery Back-up

Photoelectric Smoke and Heat Alarm Mains Powered with 10 Year Rechargeable Battery Back-up

Wire system

Connect the interconnect

Voltage

220-240VAC

View All
Residual current transformer

Residual current transformer

Input current

10A

Secondary output signal

5mA

View All
Fire blanket

Fire blanket

Model#

GTFB1218

Material

Glass fibre

View All
Combustible gas detector

Combustible gas detector

Wire system

Connect the interconnect

Voltage

12V-24VDC

View All
Wired switch

Wired switch

Standard

EN 62479:2010

Battery life

10 Year

View All
Optical Smoke Alarm 
Mains Powered with Battery  Back-up

Optical Smoke Alarm Mains Powered with Battery Back-up

Wire system

Connect the interconnect

Voltage

220-240VAC

View All
Battery Typed CO Alarm

Battery Typed CO Alarm

Model#

MINI-968D

Battery life

1-10 years

View All
Manual fire alarm button

Manual fire alarm button

Standard

GB 19880-2005

Voltage

DC24V(18V-28V)

View All
Water based fire extinguisher

Water based fire extinguisher

Model#

MSWJ620

Fire suppression class

0.5A,8B,E,5F

View All
Photoelectric Smoke and Heat Alarm
Mains Powered with 10 Year Rechargeable Battery Back-up

Photoelectric Smoke and Heat Alarm Mains Powered with 10 Year Rechargeable Battery Back-up

Wire system

Connect the interconnect

Voltage

220-240VAC

View All
Residual current transformer

Residual current transformer

Input current

10A

Secondary output signal

5mA

View All
Fire blanket

Fire blanket

Model#

GTFB1218

Material

Glass fibre

View All
Combustible gas detector

Combustible gas detector

Wire system

Connect the interconnect

Voltage

12V-24VDC

View All
Wired switch

Wired switch

Standard

EN 62479:2010

Battery life

10 Year

View All

HOME

ABOUT US

  • ABOUT US
  • MILESTONES
  • BUSINESS STRUCTURE
  • OUR CULTURE

NEWS

PRODUCTS

  • BUSINESS SCOPE
  • PRODUCTS CENTER

SOLUTIONS

  • DOMESTIC FIRE ALARM MONITORING
  • INTELLIGENT FIRE ALARM
  • COMBUSTIBLE GAS DETECTION IOT
  • SMART ELECTRICITY SAFETY WARNING
  • INTELLIGENT FIRE WATER MONITORING

CSR

CASES

JOIN US

  • TALENT PROSPECT
  • MANAGEMENT MODEL
  • WORKING ENVIRONMENT
  • EMPLOYEE EVENTS

CONTACT US

  • Shenzhen Office (SZ)
  • HKSAR Office
  • Logistics Center (HKSAR)
  • SHOP

Copyrights ©2021 GartecTechnology Co., Ltd 嘉达科建. All rights reserved

Copyrights ©2021 GartecTechnology Co., Ltd
嘉达科建. All rights reserved